High pressure gear pumps with side and rear ports wich gives ample mounting.  Bi-directional, pressure plates in bronze and nodular cast iron body for high working pressures. Flow from 11cc to 150 cc. Those pumps can be mounted directly in most of PTOs in the world.

In case of doubts during or before assembly, please contact to Bezares After Sales Service

BE Pump Rotation

Both, clock wise and counter clock wise with internal drainage

BE Pump Rotation

Units subjected to axial or radial loads must be fitted on a external coupling
with bearings which support axial and radial loads.

Torque tightness setting for fixing bolts

M10 – 50±5Nm
M12 – 85±5Nm
1/2″ – 85±5Nm

Torque tightness setting for hydraulics fittings

1/2” BSP – 60±5Nm
3/4” BSP – 90±5Nm
1 1/4” BSP – 200±5Nm
1 1/2” BSP – 250±5Nm

The shaft spline of the pump must be lubricated with heat-resistant grease
when the PTO is assembled with a built-in shaft seal. (See example in drawing)

Use exclusive good quality hydraulic oil with anti-foan and anti-wear additives. The specification of the fluid must conform to DIN 51524 / 51525 (type HLP)

Please, use the following guidelines to choose the correct oil grade:

Permissible: 8 – 800 cSt
Recommended:
10 cSt Very cold climate
32 cSt Cold climate
46 cSt Temperate climate
68 cSt Hot climate

Temperature:
Min -15ºC / Max 80ºC
Cold Start: -25ºC to -15ºC

Clockwise rotation

Counter Clockwise rotation

Filtration

Suction line: Not recommended
Return line: 10 to 25 µm

A contamination level according to ISO 4406 is recommended to maintain in the filtration system.

Find out and eliminate the source of trouble (wear accuring in normal operation, dirty fluid, load applied to drive shaft, operating conditions not observed)

BE Troubleshoot table

wdt_IDSource of troubleNo fluid deliveryInsufficient pressure and / or volumetric flowStrong or adnormal noiseFoaming in hydraulic tankFluid leakage at drive shaftFluid temperature too high
1Insufficient fluid levelXXX
2Low input pressureXX
3Suction line leakyXXXX
4Faulty shaft seal ringXX
5Gear pump faultyXXX
6Coupling faultyXX
7Wrong direction of rotationX
8Relief valve incorrectly setXX
9VibrationsX
10Piping faulty, wrong control positionX
11Operating conditions (Fluid Temp, viscosity, pressure duration of load) and / or input power not in complianceXX
Share this Page